Dan for Model Number MTB2156DEQ With the defrost timer in defrost I have 120V on blue line in and no volts on line to heater line, heater checks 0 with volt meter.I would think the thermostat is the problem.No defrost on evap.
Answer Dan, With the defrost timer in the defrost mode, you should read 120 VAC from blue(#3) to white (#1) this is power in, and from yellow(#2) to white(#1) this is power out, to the heater 120 VAC. The defrost thermostat, should have a closed circuit below 38 dgrs.F. and an open circuit above 38 dgrs. ( put the thermostat in a glass of ice water for a few minutes then check the circuit). The heater element should have a resistance reading(approximately 20 to 30 ohms, on that unit), it sounds more like a defrost timer issue, based on your post. Read More... Answered by AppliancePartsPros.com | Monday, July 9, 2012