Roger for Model Number WFW9550WR00 I have a multimeter to test if my valve has failed. I was unsure if I am supposed to test for voltage or if I am able to test for continuity. If I need to test voltage, what should it read and do I test it with the washer running?
Answer Roger, you will need to test for 120 VAC. It should be while the valve is being energized so that you can check for proper voltage. There will only be voltage going to the valve when water is being called for from the control. Read More... Answered by AppliancePartsPros.com | Friday, May 12, 2023