Stephen G San Diego , CA January 13, 2017 Water/ice limit switch sticking Removed cover by removing two torx screws, unplugged switch circuit board, then removed the three torx screws that hold the ice door assembly and unplugged the two plugs. Removed the switch held by one Phillips screw and removed the actuation pad. Cleaned everything up and reinstalled. Took a proxy 20 min. Do-It-Yourself Rating: Repair Time Estimate: 15-30 minutes