Jesse August 20, 2017 for Model Number Faqg7001lw0 Dryer stays running even when timer is done. No heat and you must open door to stop dryer. I ran the code and it came up E11. It said to replace electronic control.
1 Answer Hello Jesse, This is the code indicates a "Checksum Error". This is basically an issue with communications or the memory between the EEPROM and the microprocessor. You should first verify the polarity and proper voltage at the wall outlet. Also make sure there is a proper earth ground at the wall outlet. If clearing the code and the problem persists, replace the electronic control as per the manufacturer. Read More...