Customer Questions and Answers for Orifice Nat by Frigidaire

Best Seller
Manufacturer Part
4.89 (64)
By: Frigidaire
Part Number: OEM13088037
Manufacturer Part Number: 316527500

The Burner Orifice is an OEM part for Frigidaire cooktops and ranges. It is a critical component that controls the flow of gas to the burner, ensuring a consistent and stable flame for cooking. The orifice regulates the amount of gas released to the burner, which in turn affects the size and intensity of the flame.

Causes of a bad burner orifice can include food debris or grease build-up, corrosion from prolonged exposure to gas, or physical damage from cleaning or handling.

Symptoms of a bad burner orifice include:

  • Uneven or irregular flame
  • Burner not igniting
  • Weak or yellow flame
  • Gas smell near the burner

This OEM replacement is also compatible with Electrolux, Gibson, Kelvinator, and Kenmore models.

More
$29.95
Compare At:
$35.34
You Save:
$5.39

IN STOCK
Ships Today Guaranteed
Add to Cart

Questions & Answers

For Frigidaire Orifice Nat (Part Number: OEM13088037)

1 Answer

James L, Based on the information provided the orifices for Nat.Gas is surface units 316527504 Orifice, burner, 5K 316527500 Orifice, top burner, 9.5K 316527502 Orifice, top burner, 12K 316527509 Orifice, burner, 18.2K and the broil 316409703 the bake is adjustable and don't forget to flip the cap on the regulator.

Read More...

1 Answer

Hello Greg, You are correct but do not forget to adjust the air shutters. When adjusting back to natural gas these will need to be adjusted to about 3/4 of the way closed.

Read More...

1 Answer

Gary, the left front, left rear, and right rear orifices are part number 316527500 while the front right orifice is part number 316527502. With the gas valve shut off at the wall, and the power cord unplugged, the regulator cap can be unscrewed and flipped upside down, the air shutter can be closed to the 3/4 position, and the bake orifice hood can be loosened 1 1/2 to 2 full rotations. With this done, the flames should be blue, if there is any yellow, adjustments to the air shutter and orifice hood can be made in small amounts.

Read More...

1 Answer

Chris, the orifices are as follows: right front orifice 316527509, right rear orifice 316527504, left rear orifice 316527511, left front orifice 316527500, and center orifice 316527500. With power disconnected and gas turned off to the unit, you will need to change out these orifices then loosen the orifice hoods of the bake and broil burner 2 1/2 turns, as well as unscrewing the regulator cap to flip the gas regulating pin upside down from it's current position.

Read More...

1 Answer

Darin, The Natural Gas orifices for the right front "PowerPlus" burner are ; 316527502 / 316527502 Orifice, burner, 12K "middle) and 316527500 / 316527500 Orifice, burner, 9.5K (2 required) "both side" orifices(total of 3 orifices). The parts are in stock and available at this time. Thanks,

Read More...

1 Answer

Rick, For the model number you supplied you would need to order part number 5304486443 / 5304486443 LP Conversion Kit, w/instructions. Unfortunately the part is presently out of stock and would need to be ordered from the manufacturer. This will add a few days to the delivery time, once you place the order. Thanks,

Read More...

1 Answer

Alissa, To convert back to natural gas you will need the top burner orifices right front 316527511, right rear 316527504 and for the center left front and left rear will be part number 316527500. For the oven you would loosen the orifices 1 1/2 to 2 turns and close the air shutters to about 3/4 of the way open.

Read More...

1 Answer

Hello Debbie, the right front burner uses orifice part number 316527502 and the other three burners use part number 316527500. You'll have to turn the orifice on the gas valve counter clock wise 2 1/2 turns and flip the conversion cap on the regulator to N for use on natural gas. Thanks!

Read More...

Have questions? Ask our pros!

Contact us in a way that is convenient for you

Call us 1-877-477-7278
Need Help? Chat with a Pro
Or ask a question by filling in the form

Share your thoughts with other customers

Ask a Question