Questions & Answers

For Frigidaire Ss Console Asmy (Part Number: OEM12896667)

1 Answer

Hello Robert, once a manufacturer discontinues a part, and it goes out of stock, it is considered no longer available, there is no replacement part.

Read More...

1 Answer

Doug, With getting the PF and the lights will not come on and unit will not stop running then this sounds like it would most likely be a faulty control board.

Read More...

1 Answer

Hello Kathleen. Yes, it sounds like the control panel is bad and will need to be replaced on the unit.

Read More...

1 Answer

Hello Jason. Try reseating the ribbon cable. If the issue continues, replace the control panel. If it continues after that replace the board. Power surges can damage many electrical parts.

Read More...

1 Answer

Clayton, Based on the error that you are having, this would indeed be caused by a touch pad assembly error and will need to replace the console assembly 154639208.

Read More...
Stephen for Model Number FDB4315LFC2

I have a Frigidaire FDB4315LFC2 dishwasher. It was flashing the "CL" code, so I replaced the latch assembly. When this did not correct the problem, I replaced the control board. Now the dishwasher turns on when I press the Start button on the right, and I can change what type of wash I want with the buttons on the left, but the four center buttons that control High Temp Wash, Sanitize, Air Dry, and Delayed Start won't work. Could this be a faulty control board, or is it something else??

1 Answer

Stephen, With the 4 buttons not working, make sure that there is no corrosion on the terminals of the ribbon harness and make sure that the ribbon harness is firmly in place. If this checks ok then the most likely cause would be a defective control panel.

Read More...

1 Answer

Hello Louie. We will need to know the error code to tell you which part is bad on the unit. Thanks

Read More...

Have questions? Ask our pros!

Contact us in a way that is convenient for you

Call us 1-877-477-7278
Need Help? Chat with a Pro
Or ask a question by filling in the form

Share your thoughts with other customers

Ask a Question
  • boxes images Over 2.1 Million Parts In Stock
  • time delivery images 2 Day Quick Delivery!
  • box-refresh images 365 Day Return Policy!
  • headphone imagesFree Tech Support!
  • google images Google Trusted Store