Customer Questions and Answers for Refrigerator Main Control Board by Ge

Best Seller
Manufacturer Part
4.89 (64)
By: Ge
Part Number: OEM21656610
Manufacturer Part Number: WR55X11072C

This electronic control board manages your refrigerator's key systems—compressor, fans, and defrost. When the original board fails, you may see warm temperatures or erratic behavior; replacing it restores stable cooling and proper defrosting.

  • Regulates compressor and fan operation to maintain set temperatures
  • Controls adaptive defrost timing and energizes the defrost heater
  • Distributes power to critical loads and processes sensor inputs
  • Helps with: no cooling or intermittent cooling, compressor/fans not running, heavy frost from no defrost, or unresponsive/erratic controls
What's included: 1 main control board Install notes:
  • Disconnect power before servicing; risk of electric shock
  • Use ESD protection; handle the board by the edges only
  • Photograph and label connectors; transfer wires exactly and fully seat each plug
  • After installation, restore power and follow any model-specific service sheet/configuration steps provided with the appliance

More
$174.90
Compare At:
$182.84
You Save:
$7.94

Out Of Stock

Usually ships within 4 - 14 days

Add to Cart

Questions & Answers

For Ge Refrigerator Main Control Board (Part Number: OEM21656610)

1 Answer

ALBERT, You will need to determine what is running i.e. ...... compressor and fans. If everything is running and there is no cooling then you will likely have a sealed system Issue and would need an EPA-Certified tech for those repairs. If the fans are running and the compressor is not then you could have a control board issue.

Read More...

1 Answer

Mark, if the heater strip WR49X10173 (All metal liner SxS production built January 2003 through January 2007 serial numbers AF through AM) was installed and the water dispenser tubing in the door is still freezing, the failure would not be in the main control. This would indicate that the water line is close to the inner panel of the freezer door and the only correction at this point would be replacing the door assembly WR78X11096. The heater strip receives the voltage supply from the dispenser control wires, so if the dispenser is working, the heater should be as well.

Read More...

1 Answer

Skip, The lower thermistor should not have anything to do with the unit not defrosting and it would be recommended to check at the main control board to see if the evaporator thermistor is reading the correct resistance. The thermistor sitting on the evaporator coils should have a resistance reading of approximately 42.2K ohms of resistance. Either the thermistor being faulty or the wiring between the thermistor and the control board being faulty would likely cause this issue.

Read More...

1 Answer

Hello Mike. Try unplugging the unit and resetting it. If the issue continues, you will need to replace the main control board on the unit.

Read More...

1 Answer

Hello Randy, The defrost on this unit is electronically controlled. The "motherboard" WR55X10942C is the part that controls the defrost cycle.

Read More...

Have questions? Ask our pros!

Contact us in a way that is convenient for you

Call us 1-877-477-7278
Need Help? Chat with a Pro
Or ask a question by filling in the form

Share your thoughts with other customers

Ask a Question
  • boxes images Over 2.1 Million Parts In Stock
  • time delivery images 2 Day Quick Delivery!
  • box-refresh images 365 Day Return Policy!
  • headphone imagesFree Tech Support!
  • google images Google Trusted Store