For Samsung Assy Pcb Main;Purple (Part Number: OEM13212444)

Julie for Model Number Samsung WF448AAP/XXA

No draining error. Pump has been replaced and still same issue. Will go into drain and spin cycle if I partially drain manually. All of the drain lines have been checked for blockage. Nothing to find. My next thought is the PCB assembly, as I read this as a solution to the same exact problem another person was having. My big question is...before I order the part, this is what my PCB assembly has for a number on it: 20090119 G 0254 00133A-4C58 Now the only number on this that correlates with any of the PCB replacement parts is the 00133A.... So back to my question....what is the difference between 00133A and 00133B and 00133V, etc. as I look at them they all look identical, but not in price. Naturally the one I think i need, that ends in A is the most expensive one. My biggest concern is just that I order the correct part. And honestly I'm getting more and more confused as I search online for help with this. Thanks.

1 Answer

Julie, The most likely difference would be the connection of the drain pump and you will want to use what the original part number is which would be DC92-00133A.

Read More...

1 Answer

Hello Tim. If the thermistor is new, you will need to check the wiring harness. If it is good, replace the control board.

Read More...

1 Answer

Hello Michael, Yes the installation is just unplug one and plug the other in. There is no programming involved. You may also want to check the drain for not being clogged as this is one of the most common drain problems.

Read More...

1 Answer

Hello Ken, You will want to check to see if the pump is getting power when the unit calls or drain. If not then you will need to check the wiring and check for power at the control board for the drain. If power at control but not at drain then wiring issue. If power at control and at drain then need to replace drain pump. If no power at control board then replace board.

Read More...

1 Answer

Hello Ed. Based on the information you provided, if there is power to the control board, but it is dead, you will need to order and replace the board on the unit.

Read More...

Have questions? Ask our pros!

Contact us in a way that is convenient for you

Call us 1-877-477-7278
Need Help? Chat with a Pro
Or ask a question by filling in the form

Share your thoughts with other customers

Ask a Question
  • boxes images Over 2.1 Million Parts In Stock
  • time delivery images 2 Day Quick Delivery!
  • box-refresh images 365 Day Return Policy!
  • headphone imagesFree Tech Support!
  • google images Google Trusted Store