Jose for Model Number MDE9700AYW

My Dryer will not turn on at all. I checked the breaker and they are not tripped, I also Checked for voltage using a multi-meter and getting good voltage to the dryer. The dryer just will not turn on at all no alarm no digital display it looks like it isn't getting any power so I beleive this is the replacement part its the first place the 220 goes my question is the backing of the circuit board on my dryer is metal. I do understand it may have changed I just do not want to buy the wrong part. Is this the part I need? I would greatly appreciate your input.

1 Answer

Hello Jose. Check the terminal block on the unit and make sure it is not burned. If the terminal block is good, you will need to replace the Main control board WP35001153 on the unit. The power comes to this board first according to the wiring diagram.

Read More...

1 Answer

Bill, You're on the right track, But based on the post description, we suspect the control panel/leypad assembly 35001160 then the PCBWP35001153. We're sending you some additional information to help you determine which component is faulty. Good Luck and Thanks

Read More...

1 Answer

Hello Patrick. Dryer must be on before Service Mode can be entered. Press Chime and Temperature Keys for 3 seconds, or until 3 beeps are heard. The machine will now be in Service Mode. Upon entry into Service Mode, the Sensor Bar Touch Data is to be displayed. Exit Service Mode Press the OFF key to exit Service Mode or repeat the Chime and Temperature sequence. Hope this helps. The test keys are as follows: Wrinkle Prevent Displays “d” Display list of diagnostic codes. Then rotate the Cycle Selector Knob To sequence thru the diagnostic and help codes. Temperature Key Display software revision number. Start/Pause Start or pause cycle running but remain in diagnostic mode. Display the number of cycles ago the diagnostic code occurred. System Check Mode While in Service Mode, pressing the Time and Wrinkle Prevent keys for 3 seconds, will put the dryer into the System Check mode and "in" will display. The following table lists the various functions based on the keys being pressed. Start/Pause rotary selector dial Cycles the motor on/off. Rotate the Cycle Selector Knob to Delicates LED’s and 7 segment display flash. Rotate the Cycle Selector Knob to Sensor Dry View current cycle temperature in Celsius. Rotate the Cycle Selector Knob to Wrinkle Control Segment display is “1” for sensor bar short, “0” for sensor bar open. Rotate the Cycle Selector Knob to Time Dry View current cycle temperature in Fahrenheit. Thank you.

Read More...

Have questions? Ask our pros!

Contact us in a way that is convenient for you

Call us 1-877-477-7278
Need Help? Chat with a Pro
Or ask a question by filling in the form

Share your thoughts with other customers

Ask a Question
  • boxes images Over 2.1 Million Parts In Stock
  • time delivery images 2 Day Quick Delivery!
  • box-refresh images 365 Day Return Policy!
  • headphone imagesFree Tech Support!
  • google images Google Trusted Store