This exhaust pipe directs heated air from the dryer drum to the household vent, restoring proper airflow for efficient drying and reduced lint buildup. It's a direct-fit replacement designed to match the OEM airflow path. What it does:
Usually ships within 4 - 14 days
Drying clothes. found dry clothes and dryer off. put in next load. when press start, F-01 error. unplugged dryer and flipped breaker. waited half hour. plugged back in and turned breaker on. nothing doing. same F-01 error. unplugged dryer again. moved dryer out and checked the exhaust port for blockage. clean. left unplugged and unscrewed bottom panel to get manual. reconnected exhaust and power cord. did diagnostic per manual to rule out other faults/errors as this electronic control board is... Read more
Isolated door switch and tested switch through harness wires. Continuity found with both switch depressed and pressed on same wires. Ordered switch Wednesday night and it arrived the following Tuesday to east coast home. Read more