Kenny W San Jose , CA April 06, 2014 Appliance: Model JBP248085WH THE TERMINAL BLOCK WAS BURN AND IT DOES NOT TURN HOT. I ORDER THE TERMINAL BLOCK KIT, AND FOLLOW THE VIDEO HOW TO REPAIRE. IT IS VERY EASY.IT TOOK ME 10 MIN. Read More... 21 People found this story helpful Do-It-Yourself Rating: Repair Time Estimate: Less than 15 minutes Tools: Socket Set
Kathleen C Colorado Springs , CO June 13, 2014 Appliance: Model 91194497992 8" burner receptical melted Replaced receptical Read More... 7 People found this story helpful Do-It-Yourself Rating: Repair Time Estimate: 15-30 minutes Tools: Socket Set
Alex B Silver Spring , MD January 15, 2017 Appliance: Model GE ELECTRIC RANGE Two burnt/damaged terminal blocks I lifted the front hood and removed the back control panel cover. I then replaced two terminal blocks with the new kits. Perfect match except wires were a bit long. So I rolled them up neatly and tucked them away at the control center. Used electrical tape to band both sets of wire and protect them from the metal edges between the range and control area. I replaced the control cover and installed two new burners. Perfect installation. Read More... 5 People found this story helpful Do-It-Yourself Rating: Repair Time Estimate: 15-30 minutes Tools: Nut Drivers, Screwdrivers
Johnnie H Albertson , NC March 23, 2014 Burned block Easy fix. Read More... 4 People found this story helpful Do-It-Yourself Rating: Repair Time Estimate: Less than 15 minutes Tools: Nut Drivers, Pliers
David B Robbinsville , NC April 04, 2018 Two of the stove top burners did not heat up. I had to replace the two terminal blocks for those burners and replaced the attached wiring to the appropriate control knobs and replaced all four burner pans. Read More... 3 People found this story helpful Do-It-Yourself Rating: Repair Time Estimate: 30-60 minutes Tools: Nut Drivers, Pliers, Screwdrivers