Roseau Boy for Model Number FGHS2644KF1 FRIGIDAIRE - Side-By-Side Refrigerator Model: FGHS2644KF1 | Serial No:4A949810721 Frigidaire fridge clicking sound The original refrigerator Control Board part No: 242000411 develop a fault the relay 12V dc 0569C1 - kept clicking on/off and then after 1 minute it switched off completely. • The display shows SY - CE error code. Ordered a replacement control board, this arrived with the additional cable to connect to the original refrigerator main harness. The replacement Part No: 242009011 looks the same as the original Part No: 242000411. Connected all cable as per diagram, the refrigerator now fails to start, there is no power to the display panel, the refrigerator internal light is not on. The refrigerator is completely dead when install Control Board Part No: 242009011 Replaced the starting solenoid and evaporator fan. Do you have any idea why the replacement control board will not work with this current refrigerator model?
Answer Communication errors, SY CF & SY CE, indicate that the Main Control Board and User Interface are not interacting accordingly. SY CE : Communication Error - Communication between User Interface and Main Control Board was established at last POR, but then lost while the unit was in operation. If the Main Control Board is not able to communicate with the User Interface, the Fresh Food lights will be off. If an incompatible replacement User Interface and Main Control Board are installed, 12VDC will be present at RED and BLK wires to User Interface but the unit will not operate. Remove left hinge cover and verify 12VDC between RED and BLK communication wires (cabinet side). If voltage is correct, verify continuity of WHT communication wire between the Main Control Board and User Interface. Also, verify there is no continuity between cabinet ground & WHT communication wire. If voltage is not correct, access the Main Control Board. Locate J9-A connector on Main Control Board and check for 12VDC between RED and BLK wires. If voltage is correct at Main Control Board, check for loose connections, backed out connector pins, or broken wire between the Main Control Board and User Interface. Repair wire, if possible, and retest. After you perform the above checks and verify the wiring, the user interface board 241973711 may be needed. Read More... Answered by AppliancePartsPros.com | Friday, May 6, 2016