Rick for Model Number PLEF398CCC Is there a trouble shooting procedure for the dual element (infinite switch) p/n: 316239601 with correct ohm values you can provide. Frigidaire model PLEF398CCC Right front dual coil burner is the issue. Symptoms: 1. When the LARGE large burner is selected, only the outer ring gets hot and the inner, small burner doesn't give any heat. 2. When the small burner is selected, there's no heat at all. Trouble shooting I've done: (@ 20k ohms scale) 1, When checked bottom pin to center pin: the Large burner (pot turned CW), ohms values are 9.54 (high) to 5.26 (simmer) Small burner: (pot. turned CCW) values are 0.52 high to 2.64 low.
Answer Rick, the surface burner control 316239403KITK would need to be tested for 240VAC by placing one meter probe on the black wire of the terminal block to the terminal P7 on the control when the switch is turned on to either setting. If the voltage is not 240VAC, the control has failed. If the voltage is 240VAC, the element 316555800 has failed. The potentiometer would not be a concern as the element is turning on, it is one specific coil that is not turning on. Read More... Answered by AppliancePartsPros.com | Thursday, November 5, 2020