Going Crazy for Model Number GE MODEL GTDX180GD1WW takes several cycles to dry anything. Burner lights properly, stays on for approx. 2 minutes then cycles off. Will relight in approx. 50seconds and stay on for 45-60 seconds. This continues over and over. Gas valve solenoids resistance are all within factory specs. Tested thermostatic switches, opening and closing within recommended temps. Continuity in all switches. Heat exiting the oulet vent is only 139 degrees F. Burner is not staying on long enough to produce required temp. Should outlet temp be approx. 180 degrees F. These tests were done on high temp cotton setting, and on timed cycle. Clothes still took several cycles to dry on either setting. HELP PLEASE!!!!!
Answer Going Crazy, Sounds like an airflow issue, make sure the vent is clear and is not crimped or crushed anywhere, for the vent four-inch rigid pipe is recommended. Read More... Answered by AppliancePartsPros.com | Monday, January 6, 2020