Howard for Model Number PFS22SBSBSS Compressor is not running. I have 115VAC on the main board connector labeled compressor. There is also DC voltage on the thermistor input to the main circuit board. The circuit board and the run capacitor have been replaced. Could it be the overload relay?
Answer Howard, Yes it could be the WR08X10061 PTC/OLP assembly. You might want to label and disconnect the black and blue wires from the start device and recheck to make sure you have 115 VAC across the two wires when the control is in a run/cooling mode. You may have a broken or loose wire in the harness. If you have the voltage, then replace the PTC/OLP assembly. Read More... Answered by AppliancePartsPros.com | Tuesday, April 14, 2015