Bob for Model Number 911.43679890 I have an older kenmore cooktop and I am replacing a infinite control switch with p/n WB24X29364 the terminals on the old switch are P,L1,L2,H1,H2 the new switch terminals are H1,L2,L1,HC,P. What is the proper wiring? Thank You.
Answer Bob, You would do a direct swap of the wires from one to the other except the H2 will go to the HC terminal. Read More... Answered by AppliancePartsPros.com | Friday, March 26, 2021