Joe P for Model Number FRS26ZNHW1 I ordered a new relay and over load. The new relay only has 2 terminals while the old one had 3 terminals. The red wire went to the overload. The 2 black wires from the capacitor went to terminals 2 and 3 on the relay and the blue wire went to terminal 1. How do i wire this with the new 2 terminal relay and the overload?
Answer Joe, For this new relay the red will still go to the overload and the blue will go to the number 2 terminal on the relay, the capacitor would be left off as it is not needed. Read More... Answered by AppliancePartsPros.com | Thursday, March 14, 2019