Walter for Model Number LFC25760ST The refrigerator no longer cools. I powered down for 45 Minutes. Powered back up. The internal lights come on. I heard a faint one click. Compressor did not come on. I can hear the fan run. I understand that this could be a start relay or the compressor. Any input will help. I tried the above a few times. The same result. Thank you,
Answer Walter, the start relay 6749C-0014E can be tested for resistance and it should measure between 5 to 8.6 Ohms when testing the side where the compressor pins plug in. If the resistance is not within this range, it would need to be replaced. If it is within this range, the compressor TCA35931726 would be the likely cause of failure. Read More... Answered by AppliancePartsPros.com | Thursday, September 8, 2022