Jack for Model Number RFG297AARS/XAA my samsung fridge shuts off every couple days compressor seams to get real hot sometimes makes a popcord sound when it tries to start .fan works for awhile .i put a box fan behind the fridge. If replugging does not work for a day and it starts.water build up under slide out fridge tray.only 6 yrs old
Answer Jack, The water collecting under the tray would be caused by a clogged drain line. With the compressor getting extremely hot and shutting down and not restarting but the fans are running then this issue would most likely be caused by a sealed system issue where there is a restriction somewhere. Would want to have a service tech to check the unit. Read More... Answered by AppliancePartsPros.com | Thursday, February 16, 2017