Dale for Model Number rs261mdwp/xaa have a samsung refer compressor comes on and there is a delay before fan comes on is this correct operration
Answer Dale, This would be normal operation as they are on different circuits in the control board. Read More... Answered by AppliancePartsPros.com | Wednesday, September 13, 2017
Answer Dale, Yes that could be normal operations " F-Fan motor usually runs together with the Compressor except the Cool Select Zone function is activated. Once the door is open and closed at high ambient temperature, F-Fan motor put off its operation for one minute. Therefore, you are advised not to take it as an error. If the delay is longer than 1 minute, the voltage between GND in Main PBA and CN 75 #2 is 8-12 VDC. The voltage between GND and CN 75 #2 repeats the change from 7-12VDC to lower than 2VDC. If the voltage is correct, replace the fan motor. Read More... Answered by AppliancePartsPros.com | Wednesday, September 13, 2017