Yuri for Model Number samsung rs2577sl Samsung rs2577sl Compressor would not start. I replaced C-OIL,Main control board and start relay,now compressor run constantly does not shuts down. Inside temperature colder than shown on the front panel. When I open the refg. door some extra segments on display lights up. Power freeze button is not responding. What could be the problem?
Answer Hi. Check at the main control board part # DA41-00104M with the volt meter. Check Connector CN30 on pins 7-6 Gry- brn wires R Sensor part # DA97-01293D for 2.4-2.8 vdc. If you do not have the board output then replace it. Remove the connector (turn off unit first). Ohm out these 2 - same pins for 10,000 ohms resistance. Thank You. Read More... Answered by AppliancePartsPros.com | Tuesday, October 23, 2012