Max for Model Number RF263TEAESG/AA 02 My evap coil is icing up every week you can put in manual defrost and it's good for about a week. If the heater element was bad you couldn't defrost? So is the problem the coil temp sensor and if so what part no.? Thank you,
Answer Max, the evaporator sensor DA32-10104N is a potential cause of this issue. The sensor can be tested for resistance and should measure 4.22KO at 86°F, 6.05KO at 68°, 8.87KO at 50°, 13.29KO at 32°, 20.42KO at 14°, and 32.23KO at -4°. If the sensor tests within 10% range of the resistance at the related temperatures, then it is likely that the main control DA92-00384K is not cycling the defrost properly. Read More... Answered by AppliancePartsPros.com | Thursday, February 13, 2020