Nicholas for Model Number WED5560SQ0 Thanks for tip. I pulled the dryer away from the wall and took the back panel off, even the exhaust hose. I ran a white load of towels and clothes and they all were a little damp. What thermometer would I need to check for temperature of the air and would I still have to change the cycling/operating thermostat off even though it still has continuity?
Answer Hello Nicholas, Showing continuity does not tell you at what temperature the thermostat opens. If it has been thermally stressed, it may be opening at too low a temperature and not closing soon enough, creating a cool dry condition. The dryer exhaust that runs through the home should be checked for a full 4-inch diameter opening all the way to outside atmosphere. Read More... Answered by AppliancePartsPros.com | Friday, January 4, 2019