Nick for Model Number RBS305PDQ16 Hello Nick. if the sensor is reading 850 at room temp, it is bad. However, it does not make the board turn off. It sounds like the control board and the sensor will need to be replaced on the unit. You can test L1 on the board and see if there is 120 volts AC there. If so, board is bad. Thanks for the answer. I checked L1, L2, N, and E. All of them are 120V. The normal is 240V, right? Do I need to check the suppressor and how to check it? Thanks
Answer Hello Nick. No, L1 And L2 should be 120 volts. However, if you test across L1 and L2, then it becomes 240 volts. Read More... Answered by AppliancePartsPros.com | Thursday, January 2, 2014