Hank for Model Number WDF520PADM3 When entering service diagnostics cycle (hitting any three keys in sequence 123 123 123) all of the led's light up except 3, heavy, high temp and sani-rinse. Turned off breaker for 45 minutes hoping to reset, also let machine go through the full diagnostic cycle a few times hoping it would reset, no change, those 3 led's will not come on. Could it be anything besides control board? Thanks.
Answer Hank, If the lights come on in normal mode then yes the control board would be the issue. If the lights that do not come on are not working normally then the issue would more likely be the control panel that is faulty. Read More... Answered by AppliancePartsPros.com | Wednesday, November 25, 2015