Ko for Model Number MEDE300VW0 The moisture sensor cycle stops before the clothes are dry. Timed cycle drys the clothes properly. Cleaned the vents and ducts. Plenty of heat, plenty of airflow. Ran diagnostics and sensor strips passed the test. Measured resistance across the contacts of the cable that includes the two MOVs and it was infinity. Measured resistance between outer contacts and ground and it was infinity. Does all this point to replacing the machine control electronics? Thanks for your help.
Answer Hello KO. Try cleaning the sensor bars in the unit. If they are clean, try replacing the thermistor WP8577274 in the unit. Read More... Answered by AppliancePartsPros.com | Wednesday, October 23, 2013