Ion N for Model Number RMC275PVS01 I repaired my microwave/oven combo 3 years ago by just replacing the blown out 15A fuse WP4375321. 3 years later, it showing up the same DOOR error on the display. The same 15A fuse was blown out again so I replaced it again. However, this time, the microwave turned on for only about a second or 2 and died again (almost instantly). The 15A fuse if blown out again. I checked the door switches and they are still good. Could it be the high voltage capacitor? Also the V1 circular red capacitor on the Electronic Filter is open while the V2 red capacitor is short. Should I replace the shorted V2 capacitor? What is the part #?
Answer Ion, If the filter is showing a shorted or open capacitor then the filter would need to be replaced. Normally this issue will be a door switch that is faulty and would want to double check the switches. The primary and secondary switches are normally closed and the monitor is normally open. Read More... Answered by AppliancePartsPros.com | Wednesday, August 23, 2017