Tom for Model Number KSSC42QMS00 Fridge and freezer not getting cold. Compressor and fans are running. Diagnostics says all is good. Checked inverter box voltages: 119AC and 3.6DC. Checked compressor voltage at 230AC which is what it is rated. Check windings resistance at 6.3Ohms for all pairings. Is 6.3Ohms correct or it should be 9-10Ohms? Don't know what else could be the issue. Any suggestions? Thanks.
Answer Tom, all the numbers you have given me are good, 6-7 ohms between all the pins on the compressor is normal. Based on what you have told me, you may have a sealed system leak. If the freezer temps were normal and the refrid. was high, I would lean toward air flow or defrost issues. With both sides being above normal and the compressor and all fans are running, you probably will need a sealed system repair. Read More... Answered by AppliancePartsPros.com | Wednesday, December 12, 2018