Jonpe for Model Number GC5SHEXNSO5 2007 whirlpool gold counter side by side Stopped cooling freezer and refrigerator ice melted etc. Cleaned very dirty condenser coils and Reset by unplugging. Works fine making ice and keeps temps at 0 and 37 f for 2 days then begins to warm again. Diagnostics run shows a “2” for compressor fan failure and “2” for the compressor as well on several runs. However, after it sits a day restarting it I hear the compressor fan click on /off several times for less than 20 seconds then works fine again temps go down to normal for 2 days, and the warms again. So it’s basically intermittent failure over 2-day cycles? Could this be the compressor limit or start relay? Invertor? Not sure what part to test next or begin to replace.
Answer Jonpe, it would be recommended that the condenser fan motor is tested for 120VAC when it is clicking on and off. If it is constantly receiving voltage, the fan W10124096 has failed and would need to be replaced. If it does not receive constant voltage, the main control W10219463 has failed. Unfortunately, the main control has been discontinued and is no longer available. Read More... Answered by AppliancePartsPros.com | Monday, January 11, 2021