Ken for Model Number KSSC48QTS02 Unit stopped cooling, unplugged for a couple weeks until I had time to look at it. I cleaned the condenser area to ensure airflow and open the panel and cleaned inside of there. Powered on and the fan motor comes on for the coils but the compressor doesn’t seem to kick on. Inverter box has green light that flashes 3 times continuously. Checked the inverter box and has 120VAC come out of the black and white wires. Red and white ones have 5.6-5.9 VDC output. Is this push more towards the control panel or is there something else I should check? Thanks
Answer Hello Ken, thank you for contacting Appliance Parts Pros. That 3-blink code on the inverter [W10629033] indicates an inverter failure and that it needs to be replaced. The voltages you are seeing are actually inputs to the inverter instead of outputs. Read More... Answered by AppliancePartsPros.com | Tuesday, November 19, 2024