Katie for Model Number Whirlpool Ywet3300sq1 Hi, we have a whirlpool stackable set (model Ywet3300sq1) and over the past few months the cold and hot water was reversed on occasion - now it is all the time, with boiling hot water coming out on the cold setting. Unfortunately because all temperature cycles have a "cold water rinse" all my clothes are being washed in boiling water. Originally the water lines were hooked up wrong. We corrected that issue and it seemed fine. But then every few cycles the water temperature would go off again - and then it would be fine. We replaced the temperature switch, but it is still coming out with the wrong temperature of water. That didn't seem to correct the issue at all. Any suggestions?
Answer Katie, You will want to check to make sure that the wires connected to the valve are not reversed. On one of the harnesses there is a Yellow wire with a red stripe which will go to the cold water valve. Make sure that the wires are not crossed. It is possible that you received a fautly ATC switch W11103599 but would be more likely the wires reversed at the valve. Read More... Answered by AppliancePartsPros.com | Monday, March 21, 2016