Monskeeh for Model Number whirlpool gas dryer wgd9050xw1 my gas dryer runs as normal and finishes its cycle time only to find out that there was no heat. using a digital multi tester, i found out that: 1. thermal fuse was open (no continuity), 2. exhaust thermistor #8577274 at room temperature measures19.18 ohms at 20K setting and also there is no continuity at 200 ohms setting. 3.gas valve part# W10175144 or (W10328463) reads higher from 165 ohms to 381 ohms than the normal rating on each terminal as follows: terminal 1 to 2 should be 1365 ohms but actual reading is 1709 term 1 to 3 560 but reads 750 term 4 to 5 1220 but reads 1651 ohms thermal cut off, high limit thermostat, flame sensor all have continuity at 200 ohms setting. lint venting system seem to be clear of clogs. i hope you could help me solve my dryer's NO HEAT problem. thank you in advance.
Answer You will need to replace the thermal fuse and the gas coils on the unit based on the readings you got. Read More... Answered by AppliancePartsPros.com | Friday, May 27, 2016