Kimball for Model Number WRT779RFYB10 My freezer is not working and where the capillary tube connects with the evaporator tube. there is a significant ice build up. Any ideas on what the problem might be ?
Answer Kimball, You have a restriction in the sealed system. Most likely in the filter drier WPW10143759 . You will need a certified refrigerant technician to recover the refrigerant, check and clear the system and replace the filter drier. Read More... Answered by AppliancePartsPros.com | Tuesday, April 26, 2016