Nick for Model Number maytag mdg9316aww My gas maytag dryer will not heat, the ignite lights and stays on for about 10 to 15 seconds, then i hear a click and it goes out tried replacing the coils with same result. I've tested flame sensor, cycling thermostat, high limit thermostat, and thermal fuse with all of them checking out good. Any idea's?
Answer Nick, With the flame sensor, igniter, cycling thermostat, high limit and thermal fuse checking ok and the gas coils being replaced then the issue will be in the gas valve WP306176. Read More... Answered by AppliancePartsPros.com | Tuesday, March 4, 2014