Geoc for Model Number KitchenAid KUDS30IXBL0 I get Error Codes 6 then 1 and 6 then 2 which would indicate Water Inlet Valve is not working. However, whatever cycle I choose, water fills, washes and drains on the first wash (rinse), but does not perform (fill) on any subsequent parts of the cycle. Wouldn’t this indicate that the problem is more than solely the inlet valve, since the valve seems to work on the first portion of any cycle?
Answer GeoC, the valve WPW10327249 would need to be tested for 120VAC during a refill cycle. If there is voltage and the valve did not allow water through, the valve has failed. If there is not 120VAC, the float would need to be inspected to identify if it is getting stuck in the upward position. If it is not stuck in an upward position, the main control WPW10380685 would be the most likely cause of failure. Read More... Answered by AppliancePartsPros.com | Tuesday, July 19, 2022