Marcin September 17, 2019 for Model Number SMH1816B/XAA-0000 Looking to replace microwave thermostat. Thermostat is behind the touchpad and reads KSD-1201C. Which part number is the right one?
1 Answer Marcin, the thermostat on the left just behind the touchpad is part number DE47-20034A and the right is part number DE47-00050C. The left thermostat is a normally open thermostat used in conjunction with the vent fan and closes at 158°F to turn the vent on, preventing the control from overheating from any heat source. Read More...
Aaron September 10, 2019 for Model Number MC17F808KDT/AA-0000 I need a part # for my burned thermostat on my Samsung microwave. My defective part 1590/ KSD-150LC. This may be a convection thermostat. Thank you
1 Answer Aaron, there are six different thermostats inside this model microwave. Based on the information you did supply the replacement thermostat should be DE47-20007B / DE47-20007B Thermostat;nt-101NA,250/. The part is in stock and available at this time. Thanks, Read More...
Bret Steel August 23, 2019 I'm looking at the Samsung part # DE47-2034A. I see the switch activates at 212 degrees. Do you have a similar switch that activates at 185 degrees? Thanks Bret
1 Answer Bret, The part you have listed is available as a manufacturer recommended replacement part and our part number is DE47-20034A Read More...
Steve August 19, 2019 for Model Number 40180093700 Oven won't heat, but all other functions OK (lights, turntable, display). Three door switches OK. Found thermostat DE47-20059A is closed and DE47-20034A is open. Are those the right states for the 2 thermostats?
1 Answer Steve, the two thermostats mentioned are reading appropriately as one is for the vent fan (the open one) while the other is for cavity over temp (the closed one). You may want to inspect the magnetron thermostat DE47-20007B. Read More...
Rajnikant August 06, 2019 i have samsung me18h704sfs microwave.it turn on but didnt heat up. i did check continuity on thermo state behind panel. looks to me left thermo state is not working. it says 1505 KSD-40LC 70 on thermo state. can you please tell me which one should i order?
1 Answer Hello Rajnikant, that thermostat is a normally open type, it senses the temperature rise on the underside of the microwave if the vent is not turned on and the cooktop is being used , it will cause the vent motor to automatically start and stops the vent motor once the temperature drops. It does not affect microwave operation. For a no heat condition where the microwave seems to run and count down correctly,start by testing the door interlock switches and if they test ok then check for 120v to the primary side of the high voltage transformer ( black - black /white wires) for 120v in operation using a multimeter. If there is no 120v then replace the control board, if there is 120v then there is a problem with the high voltage section components. Read More...
John June 02, 2019 for Model Number ME18H704SFS Hey all, I'm looking for what I believe is the thermostat, but can't find the right part number. The thermostat I have is labeled KSD1 CL1 40/70. I've read this might be a normally open thermostat? I can't find a thermostat with the same part number, do you know if it goes by a different number? I also couldn't find the microwave listed, its a samsung microwave.
1 Answer John, The thermostat that would be normally open will be part number DE47-00050C. Read More...
Phil G. May 28, 2019 for Model Number GE Microwave JVM1650CH05 I am looking for a thermal cut off that is set for 100 degrees C. Do you have that part?
1 Answer Hello Phil, I'm sorry but none of the thermal cut-offs on the model provided are rated 212°F. Thank you for your patience and understanding in this matter. Read More...
Surinder January 02, 2019 for Model Number Samsung Microwave SMH1816S I don't have a schematic to connect Thermostat that seems burnt and didn't turn on Microwave. My question is how do I connect the wires to this Thermostat: 2 wires (black & yellow) on terminal 1 and a black wire on Terminal 3 or what is the correct way to connect. Thank you.
Tom Doyle December 12, 2018 for Model Number Samsung ME18H704SFS microwave Wife used the microwave to heat some food. Shortly after the whole house power cycled off/on. I went to use it shortly after and found it completely dead. Checked breaker & tested wall outlet and it is "live". Have checked all three thermal fuses, the one on top (good), and the two behind the control panel -- right side one (good) and left side one (good -- normally open). Checked the two 20 amp fuses behind the control panel on the circuit board. They both are good. Any further things to check? Yeah, I know, I should have a surge protector between the wall outlet and the microwave which I have now done. Thanks for your help!
1 Answer Tom, All the components you have tested that all check good is an indicator that a main control board failure has occurred. It is good you have a surge protector in line though for further problems. You will need to order the main control board DE92-03624B Read More...
1 Answer David, We will need your model number to help you find the right parts for your unit. Please post another question with all your info included thank you. Read More...