The door latch is opened by the lever switch, which sits on a plastic peg on the body latch - part AP3186330. This plastic peg had broken. Talking to the dealer, it sounds like a common problem. It's fairly simple to open the cabinet and remove the old part. The manual claims that the big capacitor has a self-discharging circuit, but it's best to briefly short it out with a resistor just to be sure. The biggest issue is the three electrical interlock switches that also click into place... Read more
I replaced both the fuse and the latch. it started working smoothly even better the before. Read more
The microwave suddenly stopped working. No display, no light, nothing. After opening up the microwave I checked the fuse, fire sensor and thermal overload with a continuity tester. They all checked out. With the microwave plugged in and not running, I checked voltage at several points. It was clear that the main control board was getting voltage but it was not turning anything on. I took out the control board and saw a spot where the board had obviously overheated so I concluded it... Read more
Replaced control panel assy Read more