Chris S. for Model Number FGHS2631PF2 My fridge had been acting up lately, the tempature on fridge used to go negative 30 in freezer but yet fridge goes like 50 degree. I had them set to 0 and 40. I have replaced both thermostat and now freezer stays right at 0, but fridge stays at 48 when its set to 40, and when i set it to 33, it actually brought temp down to 30, so i made it 34 or 35, it stays at 30ish. I am assuming that a circuit board is not working right. The door damper works fine. Which one of the board that controls the whole tempature in fridge so i can replace and bring it back to normal fuctioning, i have found 2 different boards there. It is interface circuit board part 242058232 or main power board part 242115260
Answer Hello Chris. That board would be part number 5304497976. Read More... Answered by AppliancePartsPros.com | Monday, March 7, 2016