Warren for Model Number 253.28052800 Control on freezer show Hi Temp and freezer does not get cold. Compressor comes on and runs forever but no cold or ice forming on evaporator. Thermistor checks within range at "32" degrees when frozen in water in my other refrigerator freezer. Compressor 3 terminal pins check correct with on at 4 and one at 8 with the other totaling 12 and none of the terminals to ground show short. This freezer was given to me and owner says it a couple years old. It looks like brand new inside and out and was kept indoors. Should I purchase a control panel and see if that's it. Oh, the relay starter is fine, I say that because it does start the compressor. I not sure about the controller since the compressor is coming on. Thanks, Warren
Answer Hello Warren, This can only be one of three things: A sealed system restriction, an inefficient compressor, or a Freon loss. In any case, the sealed system requires a Freon authorized technician to perform the repair. Read More... Answered by AppliancePartsPros.com | Monday, January 27, 2014