Answer Hello Wayne, Turn the breaker off to the unit and verify the power is off. Remove the kick panel. The pump is mounted to the bottom of the unit on a plastic bracket. The plastic bracket must be removed from the unit first because the screws that hold the pump to the bracket are not accessible while it is on the unit. Remove the wires to the pump and pull from under the unit. Now remove the bracket from the pump and put the bracket on the new pump in the same fashion it was on the old pump. Now mount the bracket back on the unit. re-attach the wires and re-establish power to the unit. Run it and check for leaks and normal operation. If there are no leaks, reinstall the kick panel. Read More... Answered by AppliancePartsPros.com | Tuesday, August 21, 2012