Kathy for Model Number CT9050SH1SS Getting a F96 error code on the display of my GE Walloven. What does the code mean? How and what should I be testing?
Answer Kathy, the error F96 is going to indicate the speed of the cooling fan is below the minimum parameter. The cooling fan would need to be checked for any debris that could be stopping it up as well as testing the speed sensor WB27T11463 for a pulsing 5VDC from pin 1 to pin 2 and from pin 2 to pin 3. If the fan does not rotate during operation but there is 120VAC being applied to it, the fan WB26X31060 would need to be replaced. If the fan is rotating but there is not a 5VDC pulse at the sensor, the speed sensor board would need to be replaced. If there is not 120VAC reaching the fan during operation or it is operating and there is a 5VDC pulse at the speed sensor, the machine control WB27X25554 would need to be replaced. Read More... Answered by AppliancePartsPros.com | Thursday, March 9, 2023