Craig for Model Number pye4557ayw Lost power to machine via bad power supply cable. Fixed that but machine will not come on. The convenience lamp won't even work? The only sign of life is the cycle timer will run.
Answer Hi Craig. You need to replace the thermal fuse part # LA-1053. It opens if there is a either heater short or the vent clogged. Clean the entire vent system and the outside hood or this will open again. You can try to jump the door switch part # WP53-0148. White wire on common and the white wire to the motor. Thank You. Read More... Answered by AppliancePartsPros.com | Friday, November 11, 2011