Hojjat M Chicago , IL July 18, 2015 Appliance: Whirlpool Commercial Gas Dryer CGM2941TQ1 Whirlpool Dryer Cgm2941tq1: The dryer would run intermittently after the 45 minute cycle would end also the push button on the front panel switch would get stuck and would not pop back up. How to replace Dryer Cycling Thermostat. Replaced the switch-pb, the cycling thermostat and thermal fuse. and everything is back to normal. it took about 30 minutes to install everything. Do-It-Yourself Rating: Repair Time Estimate: 15-30 minutes