The Board Asm Main Control is an OEM replacement part for GE refrigerators. It serves as the electronic brain of the appliance, controlling and coordinating all the essential functions and operations of the refrigerator.

Causes of a bad refrigerator main control board can include electrical malfunctions, power surges, or physical damage due to moisture or impact over time.

Symptoms of a bad main control board include:

  • The refrigerator not powering on or responding to user inputs
  • Inconsistent temperature regulation or cooling performance
  • Error codes or fault indicators displayed on the control panel
  • Individual components or systems, like the ice maker or defrost cycle, not functioning properly

This GE replacement part is also compatible with Hotpoint, RCA, and some Kenmore models.

More
$304.30
Compare At:
$327.19
You Save:
$22.89

IN STOCK
Ships Today Guaranteed
Add to Cart

Questions & Answers

For Ge Board Asm Main Control (Part Number: OEM21564309)

1 Answer

Barb, You will want to check the temperature sensors in the unit to make sure that they are good. The resistance should be about 5K ohms at room temperature. If these test ok then the main control would be the main control board.

Read More...

1 Answer

Hello Mark. You will need to check and see if the damper assembly is bad and needs to be replaced. Check and see if the door is broke on the damper.

Read More...

1 Answer

Hello Juan, The main board WR55X10942C is most likely experiencing failure if the lights are all that will work. Be sure to check the wiring harness at the door hinge.

Read More...

1 Answer

Brian, With the unit running constantly you will want to check the evaporator coils in the freezer behind the wall inside the unit. If the coils are impacted with ice It sounds like you may have a defrost problem with the unit. Check and see if there is any frost build up on the back wall of the freezer. If so, you will need to test the defrost heater and the defrost thermostat. They should read closed for continuity when cold. You can test this with a multi-meter TJMA-DMT3. I will include a link at the end to assist you how to use the multi-meter if needed. If both parts are good, you will need to replace the defrost timer. Once the problem is repaired, you will need to thaw out the ice on the coils before the unit will operate properly. http://forum.appliancepartspros.com/oven-repair-including-ranges-cooktops/4810-how-check-continuity-ohmmeter.html

Read More...
Bob K for Model Number gsl251frf-bs

My G.E Side By Side is acting up. The freezer temp is good at approx 0 degrees and the frig side is good for awhile but after about 2 weeks it will start to get warm on the frig side so I am sure the coils are freezing over, because if I unplug it for a couple days it will run fine but some times it seems to run a lot and sometimes I have to manually open the small trap door so that the frig side will get cold ( not often but I do once in awhile. ) and some times to get it to stop running I have to turn the freezer selector to 0 the back to 3 and it stops running. I live in an area where we occasionally have power outages / surges and a couple years back I had to replace the circuit board because it was doing all kinds of crazy things like the ice dispenser wouldn't drop the ice and the light on the front of it would dim. would the circuit board cause my issues I am currently having? And if so is there anything I can do to protect the new circuit board from this happening again. Thanks for your time.

1 Answer

Bob, If the damper is not opening and closing and the unit is not going through defrost then it does sound like the control board would be the issue. The only way to protect the unit from surges would be to add a single plug surge protector behind the unit. This will help with surge issues.

Read More...

1 Answer

Hello Dave, You will need to order WR62X10055 for the solenoid needed to aid in the flap closing. Also, make sure the spring is good.

Read More...

Have questions? Ask our pros!

Contact us in a way that is convenient for you

Call us 1-877-477-7278
Need Help? Chat with a Pro
Or ask a question by filling in the form

Share your thoughts with other customers

Ask a Question
  • boxes images Over 2.1 Million Parts In Stock
  • time delivery images 2 Day Quick Delivery!
  • box-refresh images 365 Day Return Policy!
  • headphone imagesFree Tech Support!
  • google images Google Trusted Store