Jason May 09, 2013 for Model Number GSS22SGPASS I have a GE frig model GSS22SGPASS.PLease advice me the right model# for DEFROST HEATER KIT?
1 Answer Hello Jason. Based on the model number you provided, WR51X10101 is the correct defrost heater for the unit. Read More...
Nancy May 07, 2013 for Model Number GSH25JFTAWW The coils in the freezer keep freezing up causing the frig to get warm. A repairman checked the heating element and thought it was ok, but replaced it with a new one. Both were singles. It's still freezing up. After reading several articles, I'm under the impression that a double one is suggested as a replacement. Am I understanding this correctly?
1 Answer Hello Nancy. Either is fine as long as it was the correct one for the model number. If the heater is good and the thermostat is good, you will need to order and replace the main board on the unit. Read More...
Bree May 07, 2013 for Model Number gsh25jftcbb My water line keeps freezing up, and won't dispense ice. I followed the advice and disconnected the tubing and when pressing the water dispenser it did dispense water on the floor so knew it was frozen in the door. Can you tell me what part I need to replace to prevent this from continuing to happen?
Mark March 20, 2013 for Model Number GSS23QGTWW How do you remove the evaporator coils to install a new heater & bracket assembly? We already replaced the thermostat and seem to be working ok.
1 Answer Hello Mark, You do not, for any reason, remove the evaporator coils. If you do the freon will escape and the unit will not cool. Simply remove the back wall of the freezer compartment and there will be two screws at each heating element to remove it. The wires are routed down each side of the coils and the harness plugs in at the top. Read More...
Linda February 22, 2013 for Model Number 363.50627000 My kenmore sidebyside is working great but the deforsted water is not going down the drain to the pan below, so it is frezing up on the bottom of the frezer, when the bottom is full of ice, the new deforst water just runs over the top out the door on to the floor. ??? Do u know what is causing this I have clean out drain and found nothing.
1 Answer Hello Linda. The only way this happens if to have something in the drain hose preventing the water from draining. You will need to blow out the hose on the unit until hot water flows freely though the hose. Read More...
Ken W January 30, 2013 for Model Number 106 72522110 Refrigerator is in an unheated garage. It recently shut down in the cold weather. I understand there is a kit to prevent this. Can you help?
Bj January 22, 2013 for Model Number HSM25GFTA The water dispenser line on my hotpoint/GE frig keeps freezing...is this the appropriate part for this problem...there is nothing wrong with the freezer itself, just the water dispenser line...ice is being made fine so it seems to be from the ice maker to the door dispenser...any advice would be much appreciated!
1 Answer Hello BJ, For the water dispenser line freezing you will want to install kit part number WR49X10173 Read More...
Tm430 January 05, 2013 for Model Number GSH25JSTASS I replaced the defrost heater and the thermostat part# wr51x10055 andwr50x10068 about 2 months ago, it seems like the problem is happening again because im seeing frost on the back wall of the freezer again. in reading some of the other letters it was mentioned that there was 3 thermostats 2 with the same part# and 1 with a different one. Also after the new parts were installed the freezer made a gurgling noise then it stopped and the frost showing up. I still can't fiind out how to ck continuity on the heater and thermostat.
1 Answer Hello TM430, For a defrosting issue and you have already changed the defrost heater and thermostat it would more than likely be the evaporator thermistor WR55X10025 and control board WR55X10942C that need to be replaced. Here is a link that will show you how to check continuity and resistance. You can test this with a multi-meter TJMA-DMT3. Here is a link on how to use a multi-meter. http://forum.appliancepartspros.com/oven-repair-including-ranges-cooktops/4810-how-check-continuity-ohmmeter.html Read More...
Cbbracci December 15, 2012 for Model Number GSH25KGRE BB I have a GE side by side refrigerator and the coils all frosted over. I tested the defrost thermostat and it showed .02 ohms. Heater shows that it is open. I'm guessing that I should replace the heater and since I am in there replace the thermostat?
1 Answer Hello Cbbracci, The heater WR51X10055 will definitely have to be replaced but it's up to you if you want to replace the defrost thermostat WR50X10068. Read More...
Lillian November 17, 2012 for Model Number PSC25nstass I checked my defrost heater and found it has 21.8 ohms. I noticed that one of the wire terminals connecting to the heater burned out. Could it be the problem the heater although having coninuity is not working? Here is my problem: The entier evaporator is covered with ice. I have changed the two hermisters in the freezer and the main contorl board. The problem of warm refrigerator still exists. I have ordered the heater, but was wondering whether I also need to change the burned wire terminal.
1 Answer Hello Lillian. Yes, if the wire is burnt, you will need to repair the terminal on the wire as well. Read More...