Joe April 02, 2019 for Model Number FGHC2345LF2 My refrigerator shuts off by itself every other day or so, and the front panel read off in both spot where the degrees are read. So I hold the power button on for a few seconds and ref. Starts up fine and run great for a day or two, and then shut off automatically again. This has been going on for couple week now. What do you think- maybe main control panel? Its a side by side frigidaire about 5 years old.
1 Answer Joe, you may want to check the main control at connection J9 during failure. If the main control is tested from red probe of multimeter to pin 1 red wire to black probe on pin 2 black wire, you should read 12VDC. If there is 12VDC shown when in failure, then the user interface [242115004] has failed and is causing this issue. If there is not 12VDC during failure, then the main control [5304497863] has failed. Read More...
Tommy December 01, 2018 for Model Number LPHS2687KF0 I have a Frigidaire Refrigerator and I'm only getting crushed ice. I checked out my solenoid and found it to be bad. I replaced my solenoid but still no go. So obviously my solenoid is not getting power. Could that be a problem with my main board?
1 Answer Tommy, The main board, not likely, since everything else works properly. First check the wiring harness at the freezer door hinge, make sure there are no loose, broken or damaged wires. The access the dispenser control board 241973711 / 241973702 and check to make sure there isn't any loose connections discoloration or burn marks on the board or tracers replace the board if all's OK. Read More...
William November 13, 2018 for Model Number FGHB2844LFE Display reads SY EF so I replaced the evaporator fan/motor and it still does not work. When I did the tests, after installing the new fan/motor they all seemed to work fine except test 15, which is Evaporator fan. Any idea what to do? I was thinking replace the main board but not sure? Display still reads SY EF a few minutes after running the diagnostic tests and fan does not turn on.
1 Answer William, That error is for the evaporator fan circuit which includes the main board. So if you have already replaced the fan and still have the same issue, you will need to replace the main control. Read More...
Bruce Brown November 09, 2018 for Model Number FGHB2844LFE I was having problems with my fan not working in the Ice maker checked the fan on a 12v battery and it worked fine I was also getting 12v at the Red Wire on the fridge I disconected the other wire going to fan and grounded it to the fridge frame and every thing is off now ecept the fan on the compressor Have I burned it up retired auto mechanic ?
1 Answer Bruce, It sounds like this issue may be caused by the main power board on the unit if the unit is not working after grounding it out. Read More...
Michael July 30, 2018 for Model Number frigiodaire modelb #LGHB2869L I have a reocurring SY EF error code on the front panel, how i can resetting this problem? Any ideas which board i should replase.Thank You,Michael.
1 Answer Michael, this error code is for the evaporator fan motor, It is located in the freezer section, check to see if it is running by holding the door switch down, if it is not running you will need to replace it, part number is 809069220 Read More...
Battery Bill June 27, 2018 for Model Number LFHB2741PF1 Ice maker apparently getting big clumps ice... not dispensing. Was filling big cup, ran & ran, then sounded funny... stopped, and SY CF error. Removed ice tray, pored out ice. Noticed thermister wire?? dangling... probably why ice was frozen? Now, ice and water dispense silent. Refrig and bottom freezer interior lights (LED?) not functioning. I've unplugged a couple of times, 15 to 30 minutes. Comes on, User Interface beeps, looks normal displaying temps, then SY CF error returns within seconds. I can press menu, all functions on User Interface appear to be working. I turned icemaker off (on interface). Ideas / suggestions??
1 Answer Battery Bill, For this issue the most likely cause will be the main power board that is faulty and the icemaker would need to be replaced due to that thermistor hanging it most likely shorted and took out the board. Read More...
Eddie February 15, 2018 for Model Number phs66ejsbo I can't locate the main power board. no power on door. mfg date 4-08 frigidaire professional model jsi-26 no access panel on rear no obvious behind kick panel help?
1 Answer Eddie, This units main board is behind the controls in the refrigerator section but will not control the dispenser. With the dispenser not working this will most likely be a faulty dispenser board 241708202. Read More...
Derryk October 03, 2017 for Model Number fghn2866pf0 Fridge interior lights do not work. The freezer lights however do still work. I'm receiving a 5ycf error message. Compressor still runs and the fridge is staying cool. I have tried unplugging and plugging back in but no change. Any suggestions? Thanks!!
1 Answer Hello Derryk. You will need to check all your wiring on the unit. The error code your getting is for a sync error between the boards. If all the wiring is good, then your next step is replacing the main board 241996363 on the unit. Read More...
1 Answer Hello Bryan. We will need your model number to help you with this. Please call 1-877-477-7278 or post your model number with a new question on the parts page. http://www.appliancepartspros.com/modelnumber_locator.aspx Read More...
Dane Hendrickson August 21, 2017 for Model Number LGUS2642LE2 I have a reoccurring SY CE error code on the front panel...resetting for 15 minutes usually works for a day and then the error comes back. Noticed that the refrigerator is still cooling like it's suppose to but the ice maker, interior lights, water dispenser and ice dispenser are not working. Lights were flickering before the error code popped up. Any ideas which board I should go with first? I have extensive knowledge of circuit diagnostics if you have a way of testing the wiring. Thanks!
1 Answer Dane, For this error code it is a communication error and would want to start by replacing the dispenser control board 242114904. Unfortunately the manufacture does not give a board breakdown to be able to test it. Read More...