1 Answer

Leslie, The SY CE error code is a communication error at power up. You will want to check the wiring between the main control board and the user interface as best as possible. If the wiring checks ok then replace the user interface and if the problem persists then replace the main control board. The part number for the user interface board is 241973711 and the main control board is 5303918498. When checking the wiring there is only so much you can check. The most important thing will end up being the connections to make sure that there are no burnt or loose connections.

Read More...

1 Answer

Tristan, If the user interface in the refrigerator compartment is not showing a the display then you will want to check the interface to see if it is getting 12 vdc to it. This would be don on the black and red terminals. If there is not power there then the main control board 241511102 is faulty and would need to be replace and if there is power there then the User interface [240596701] would need to be replaced.

Read More...

1 Answer

Hello Edelvalle, The first thing you should check is the wiring harness to the door. If this has gotten dis-connected, it will cause this issue. The problem could be the power supply on the board but it would not be feasible to replace it without making this easy obvious possibility.

Read More...

1 Answer

Jack, The SY CE is a communication issue between the main control board and the dispenser control board. In most cases when this happens the main cause for the issue is the main power board 242115240.

Read More...

1 Answer

Craig, The issue is a evaporator fan circuit failure and you will want to check wiring between evaporator fan and Main Control Board. Check for 12VDC to fan between red and brown wires. Check for variant voltage (depending on high or low speed) between yellow and brown. If correct replace evaporator fan. If error code still exist, replace Main Control Board.

Read More...

1 Answer

Mitch, The Ef error is an indication that there is an evaporator fan circuit failure. You will need to check wiring between evaporator fan and Main Control Board. Check for 12VDC to fan between red and brown wires. Check for variant voltage (depending on high or low speed) between yellow and brown. If correct replace evaporator fan. If error code still exist, replace Main Control Board.

Read More...

1 Answer

Martin, No, most refrigerators don't have air filters(including yours) and most odors are from an outside source (something you put in the refrigerator) or from sitting for extended periods with the doors closed, allowing any previous odor to intensify. There's not much you can do, once you've washed the complete interior out with hot soapy water and rinsed it out(don't forget the door liner and gaskets as well). You can attempt to de odorize the interior using Baking Soda,Activated Charcoal, Coffe Grounds, Vanilla Extract, or Fabric Softner Sheets

Read More...

Have questions? Ask our pros!

Contact us in a way that is convenient for you

Call us 1-877-477-7278
Need Help? Chat with a Pro
Or ask a question by filling in the form

Share your thoughts with other customers

Ask a Question
  • boxes images Over 2.1 Million Parts In Stock
  • time delivery images 2 Day Quick Delivery!
  • box-refresh images 365 Day Return Policy!
  • headphone imagesFree Tech Support!
  • google images Google Trusted Store