Rodney January 30, 2020 for Model Number LRA18HMU210 This unit works perfectly EXCEPT the fan motor will not stop. I even ordered a replacement remote and when it is powered off by the remote, or otherwise, all of the power goes off on the display BUT the fan motor continues to run. I was wondering if it is the fan capacitor that needs to be replaced or possibly another part. Any advise would be helpful as this thing is driving me nuts.
1 Answer Hello Rodney, the fan motor run relay on the main control board is stuck closed, the board is part 5304483065. Read More...
Dave August 01, 2018 for Model Number FRA18MT2 I have ordered capacitor 5304482883 because it was obviously blown and bad. My question is where is the compressor capacitor located so I can replace it at same time? Schematic shows compressor and fan capacitor as separate. Dave for Model Number FRA182MT2 18,000 BTU window ac ANSWER Dave, the compressor capacitor is located up in the console, it is part number 5304475736 Answered by AppliancePartsPros.com | Wednesday, August 1, 2018 My question is exactly where is the compressor capacitor located. It does not appear to be in the same cavity as the fan capacitor. Where is the 'console'?
1 Answer Dave, The 5304475736/5304475736 Capacitor, comp. is located in the rear of the chassis, you'll need to slide the chassis out of the cabinet/casing you'll find the compressor capacitor attached to the side support wall of the condenser fan shroud/housing. Read More...
Dave August 01, 2018 for Model Number FRA182MT2 18,000 BTU window ac I have ordered capacitor 5304482883 because it was obviously blown and bad. My question is where is the compressor capacitor located so I can replace it at same time? Schematic shows compressor and fan capacitor as separate.
1 Answer Dave, the compressor capacitor is located up in the console, it is part number 5304475736 Read More...
Wesley September 17, 2016 for Model Number CAE25EHQ2 It will not turn off are on by remote are manual steady beep and show 60 degrees on control front only way to stop its is by pulling the plug from the wall.this time it's has stop and will not turn back on
1 Answer Wesley, This issue would most likely be caused by a faulty main control board which is part number 5304537874. Read More...