This electronic control board is the appliance's main PCB that manages functions and the user interface. Replacing a failed board can restore normal operation when the unit is unresponsive, erratic, or displaying control-related errors.

  • Directs operation of key components based on user settings and sensor feedback
  • Powers and communicates with the display/interface and control pads
  • Coordinates timing through relays and interfaces with safety/protection circuits
  • Common symptoms: no response to buttons, dead/blank display, unexpected cycling or beeping, control error codes, or visible damage on the old board
What's included: 1 electronic control board Install notes:
  • Disconnect power before servicing and verify no voltage is present
  • Use ESD precautions; handle the PCB by the edges and avoid flexing it
  • Photograph/label connectors; transfer each to the same location on the new board, matching any jumpers or DIP-switch settings if present
  • After installation, restore power and run the model's test/diagnostic or a cycle to confirm proper operation

More
$141.41
Compare At:
$166.86
You Save:
$25.45

IN STOCK
Ships Tomorrow Guaranteed
Add to Cart

Questions & Answers

For Frigidaire Electronic Control Board (Main Pcb) (Part Number: OEM17209380)

1 Answer

Hello Kenneth, check if the beeping shows its time to clean the filter, is a fault code showing in the display, if neither then likely the Display/Control board may be failing, part 5304477181.

Read More...

1 Answer

Brad, with the power supply cord unplugged, there will be screws securing the front panel located just behind the filter. Once these screws are removed, the front panel would pull forward, exposing the display control and the main control.

Read More...

1 Answer

Brad, based on the information provided, the display PC board 5304477181 would be the cause of failure as the main power board has been replaced.

Read More...

1 Answer

Hello Larry, according to the Usage Guide that came with your model to change the temperature readout, "PRESS AND HOLD THE UP/DOWN BUTTONS (ICONS) TOGETHER FOR 3 SECONDS".

Read More...

1 Answer

JKMHB, You will want to check to see if there is power from the control board to the compressor. If there is not then the board is faulty and would need service. If there is power then the capacitor would likely be the issue.

Read More...

1 Answer

Hello Joey, This will most likely be caused by a bad Main Power Control PC Board. If you could please post a new question including the complete model number we can provide you with the correct part number for your unit. Thank you for your patience and understanding in this matter.

Read More...

1 Answer

Avif, With the compressor running with the unit off then this would be a stuck relay on the main control board which will need to be replaced.

Read More...
Mark A. for Model Number LRA187MT2

Our Frigidaire A/C unit has stopped cooling. After the compressor stopped working for a short while it would work if you turned the thermostat way down. Now, the compressor never kicks in, though the fan runs fine. We took it apart and checked the run capacitor and it checked out fine at 38.8 µF. So we unhooked the ambient temperature sensor and turned the unit on. We got the "AS" error message but the compressor turned on (good think too -- it's hot out!). For now we are running it without the ambient temp sensor (manually turning it on and off), but it would be great if the thermostat worked! We tested the sensor we removed with a multimeter and the resistance does go up when the temp goes down. Do you think it is the temperature señor, or could it be the board?

1 Answer

Hello Mark. It sounds like the board is bad and will need to be replaced on the unit.

Read More...

Have questions? Ask our pros!

Contact us in a way that is convenient for you

Call us 1-877-477-7278
Need Help? Chat with a Pro
Or ask a question by filling in the form

Share your thoughts with other customers

Ask a Question
  • boxes images Over 2.1 Million Parts In Stock
  • time delivery images 2 Day Quick Delivery!
  • box-refresh images 365 Day Return Policy!
  • headphone imagesFree Tech Support!
  • google images Google Trusted Store