The Thermal Limiter is an OEM part for Frigidaire dryers. It acts as a safety feature, designed to prevent the dryer from overheating by shutting down the appliance when the internal temperature exceeds safe limits. 

Symptoms of a failing Thermal Limiter include:

  • The dryer failing to start or stopping abruptly during a cycle
  • No heat being generated while the dryer is running
  • The dryer overheating or feeling excessively hot

Common causes for a bad thermal limiter include restricted airflow due to a clogged lint filter or venting system, component failure from age or faulty manufacturing, and unusually high operating temperatures from overloading the dryer or mechanical failures elsewhere in the system. When a thermal limiter trips or fails, it must be replaced to restore functionality to the dryer.

This OEM replacement is also compatible with Electrolux, Gibson, Kelvinator, and Kenmore models.

More
$11.95
Compare At:
$14.22
You Save:
$2.27

IN STOCK
Ships Tomorrow Guaranteed
Add to Cart

Questions & Answers

For Frigidaire Thermal Limiter (Part Number: OEM6324555)

1 Answer

Hello Shelley! No, they are not the same. The cycling thermostat is located on the blower housing and is part number 131298300. The thermal limiter is also known as the thermal fuse and is located by the element, part number 134120900. Thanks.

Read More...

1 Answer

Hello Jill. It sounds like the control board is bad and will need to be replaced on the unit.

Read More...

1 Answer

WM. J. The cycling thermostat would cause the units heater to stay on to long and if the hi limit does not cut out then the unit will overheat.

Read More...

1 Answer

Ben, If the dryer motor is not turning with the drum empty then the motor would be bad. If there are clothes in it and it is not starting then you will want to make sure that the unit is not overloaded. If not then the motor would be the problem.

Read More...

1 Answer

Frank, The dryer not stopping when it gets to 0 would indicate a stuck motor relay on the control board and the control board 134557200NH would need to be replaced.

Read More...

Have questions? Ask our pros!

Contact us in a way that is convenient for you

Call us 1-877-477-7278
Need Help? Chat with a Pro
Or ask a question by filling in the form

Share your thoughts with other customers

Ask a Question
  • boxes images Over 2.1 Million Parts In Stock
  • time delivery images 2 Day Quick Delivery!
  • box-refresh images 365 Day Return Policy!
  • headphone imagesFree Tech Support!
  • google images Google Trusted Store